UPS and generators, tested on a schedule.
Every test is logged with date, technician, system, result and corrective action. Logs are retained for five years.
The answers we give providers and procurement teams during due diligence: power, cooling, physical security, network, and operations. Supporting logs and policies are available under NDA.
GPUs install directly on the motherboard over PCIe, with no risers, and sit behind enterprise-grade cooling and power delivery. Every node runs inside our own biometric cage.
Independent A and B utility feeds run through their own transfer switches, UPS and distribution down to each cabinet. The generator plant backs both sides. Either path can fail without interrupting power.
N+1 cooling units, so a full unit can drop out without affecting thermal stability. 36-inch raised floors for airflow and continuous environmental monitoring of temperature, humidity and airflow.
VESDA early-warning smoke detection and clean-agent suppression integrated with HVAC. NFPA 75 and 76 aligned systems last inspected and certified by a licensed fire-protection contractor in Q2 2026.
An active emergency refueling agreement: 4-hour response, 24/7/365, priority dispatch. Ultra-low sulfur diesel, a 48-hour on-site reserve, and fuel quality testing every six months.
Every test is logged with date, technician, system, result and corrective action. Logs are retained for five years.
No shared cage, no shared cabinets, no co-mingled hardware. CCTV is tied to badge and biometric events, so every entry can be matched to a person and a recording. Access logs are kept for 12 months and reviewed weekly.
Lumen dedicated internet access over dual-path diverse fiber, with BGP routing and automatic failover between routes.
Redundant firewalls in a high-availability pair with IDS/IPS. Public addresses terminate here; servers stay on private networks.
Zero-trust separation across compute, storage, management and tenant VLANs, plus an isolated out-of-band BMC network.
External access only through NAT, reverse proxy, load balancer, VPN or API gateway, each as an approved, logged firewall rule.
An on-site NOC watches power, cooling, network, GPU health and access events. Alerts trigger triage and, where needed, a technician dispatched to the cage.
Tell us the workload and we will come back with a configuration and price. Our security policy, maintenance and access logs, refueling agreement and certifications are available to qualified buyers under NDA; mention it in the notes.